Printer-friendly versionBack to Three Way Valves

IQ Valves, Inc.

 

2-Way & 3-Way Solenoid Valve Specifications

Operating Characteristics
Body Internal Parts: Brass
Seals: Flourocarbon (FKM)
Media: Air, Inert Gas, Call Factory for other media
Media Temperature: -40 to 185 F
Ambient Temp. Rating: -4 to 122 F
Vacuum Capacity: Consult Factory
Leakage: 2cc/minute max.
Service Life: 20 million Cycles
Cycles/sec: 50
Filtration: 40 micron
Testing: 100% Factory Tested

 

Electrical Characteristics
Coil Construction: Thermoplastic
Lead Wire Size: System 6 - 24 AWG
System 8 - 20 AWG
Voltage Tolerance: 10%
Power Consumption: Refer to chart
Nominal Power: Refer to chart
Electrical Connections: Lead wire or DIN
Pull-in Time: AC: System 6: 10 msec
System 8: 12 msec
DC: System 6: 15 msec
System 8: 20 msec
Drop out Time: AC: System 6: 7 msec
System 8: 10 msec
DC: System 6: 7 msec
System 8: 10 msec

 

System 8, 2-way Normally Closed

Orifice Size Max Pressure Watts
0.032 (0.8) Call factory 1.1
0.032 (0.8) 220 2.5
0.047 (1.2) 150 2.5
0.062 (1.6) 150 2.5
0.078 (2.0) 150 6.0
0.094 (2.4) 90 6.0
0.109 (2.8) 45 6.0

 

System 6, 2-way Normally Closed

Orifice Size Max Pressure Watts
0.024 (0.6) Call Factory Call Factory
0.032 (0.8) Call Factory Call Factory
0.047 (1.2) 120 2.9
0.062 (1.6) 80 2.9
0.078 (2.0) 25 2.9

 

System 8, 3-Way Normally Closed

Orifice SizeStop DiameterMaximum Pressure Watts
0.032 (0.8)0.039 (1.0)120 1.1
0.032 (0.8)0.039 (1.0)150 2.0
0.047 (1.2)0.059 (1.5)150 4.8
0.062 (1.6)0.067 (1.7)150 6.0
0.078 (2.0)0.067 (1.7)90 6.0
0.094 (2.4)0.067 (1.7)60 6.0
0.109 (2.8)0.067 (1.7)40 6.0

 

System 6, 3-way Normally Closed

Orifice SizeStop DiameterMaximum Pressure Watts
0.024 (0.6)0.028 (0.7)120 0.8
0.032 (0.8)0.035 (0.9)120 1.3
0.032 (0.8)0.035 (0.9)150 2.0
0.047 (1.2)0.043 (1.1)100 2.9
0.062 (1.6)0.043 (1.1)80 2.9
0.078 (2.0)0.043 (1.1)45 2.9

 

 

IQ Valves, Co. • 425 West Drive • Melbourne, Florida 32904
Phone: (321) 729-9634 • Fax: (321) 768-8732 • Email: sales@IQvalves.com